OEM/ODM Supplier Acetic Acid Urine Test - Formyl dimethylamine – Debon

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We offer wonderful energy in high-quality and improvement,merchandising,product sales and marketing and advertising and procedure for Acetic Acid 13c Nmr , Acetic Acid Topical , Acetic Acid Quality , Our aim is to help customers realize their goals. We are making great efforts to achieve this win-win situation and sincerely welcome you to join us!
OEM/ODM Supplier Acetic Acid Urine Test - Formyl dimethylamine – Debon Detail:

Identification

Chinese nanme:N,N-Formyl dimethylamine Dangerous Goods Code: 33627
English name :N,N-dimethyl formamide;DMF UN number: 2265
Molecular formula: C3H7NO CAS No.: 68-12-2 CAS号:68-12-2

Physical and chemical properties

Appearance and traits

A colorless liquid with a weak, special odor.

Melting point (°C)

-61

Relative density (water = 1)

0.94

Relative density (air = 1)

2.51

Boiling point (°C)

152.8

Saturated vapor pressure (kPa)

3.46/60℃

Solubility

Miscible with water, soluble in most organic solvents.

Toxicity and health hazards

Route of invasion

Inhalation, ingestion, percutaneous absorption.

toxicity

LD50: 2800mg/kg (rat oral); 5000mg/kg (rabbit percutaneous)

Health hazard

LC50: 9400 mg/m3, 2 hours (mouse inhalation)

First aid method

Acute poisoning: mainly eye and upper respiratory tract irritation, headache, anxiety, nausea, vomiting, abdominal pain, constipation and so on. Liver damage usually occurs several days after poisoning, the liver is swollen, the liver area is painful, and jaundice can occur. If the skin is absorbed by poisoning, the skin may have blisters, edema, and sticky, local numbness, itching, and burning. Chronic effects: skin, mucous membrane irritation, neurasthenia syndrome, low blood pressure. There are also nausea, vomiting, chest tightness, loss of appetite, stomach pain, constipation and liver and liver function changes.

Burning explosion hazard

Flammability

combustible

Combustion decomposition product

Carbon monoxide, carbon dioxide, nitrogen oxides.

Flash point (°C)

58

Upper explosion limit % (v%):

15.2

Auto-ignition temperature (°C)

445

Lower explosion limit % (v%):

2.2

Construction fire risk classification

Stability

Stability

polymerization hazard,

no polymerization

Incompatibility

Strong oxidizing agents, acid chlorides, chloroforms, strong reducing agents, halogens, chlorinated hydrocarbons.

Dangerous characteristics

Flammable, in case of fire, high heat or contact with oxidizing agents, there is a risk of fire and explosion. It can react violently with concentrated sulfuric acid, fuming nitric acid, and even explode. Strong reaction with halides such as carbon tetrachloride.

Storage and transportation conditions

Storage and transportation conditions: Store in a cool, ventilated warehouse. Keep away from fire and heat. It should be stored separately from oxidants, reducing agents, halogens, etc., and should not be mixed. Lightly load and unload during handling to prevent damage to packaging and containers. The tank (tank) used in transportation should have a grounding chain, and a hole partition can be arranged in the tank to reduce the static electricity generated by the shock. It is strictly forbidden to mix and mix with oxidants, reducing agents, halogens, food chemicals, etc. The vehicle exhaust pipe carrying the item must be equipped with a fire-stop device, and it is forbidden to use the mechanical equipment and tools that are prone to sparks. When transporting by road, follow the prescribed route and do not stay in residential areas and densely populated areas.

And leak handling

Leakage treatment: evacuate personnel from the contaminated area to a safe area, prohibit unrelated personnel from entering the contaminated area and cut off the fire source. It is recommended that emergency personnel wear a poison mask and wear chemical protective clothing. A small amount of leakage: the emulsion is washed with a non-flammable dispersant, and the washing solution is diluted and placed in a waste water system. A large number of leaks: build dikes or digging pits, cover with foam, and reduce steam disasters. Transfer to a dedicated collector with an explosion-proof pump, recycle or transport to a waste disposal site for disposal.

Product detail pictures:

OEM/ODM Supplier Acetic Acid Urine Test -
 Formyl dimethylamine – Debon detail pictures


Related Product Guide:

We emphasize progress and introduce new solutions into the market each year for OEM/ODM Supplier Acetic Acid Urine Test - Formyl dimethylamine – Debon , The product will supply to all over the world, such as: Madras , Lahore , Miami , With excellent products, high quality service and sincere attitude of service, we ensure customer satisfaction and help customers create value for mutual benefit and create a win-win situation. Welcome customers all over the world to contact us or visit our company. We will satisfy you with our professional service!
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Irma from Mauritania - 2018.03.03 13:09
    Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Philipppa from Bulgaria - 2017.01.11 17:15
    Write your message here and send it to us